Anesthesia Aeon8600A Machine
Anesthesia Machine Aeon8600A
Specifications:
Physical & Environment Specifications
- Dimensions (W×H×D): 704 mm × 1403 mm × 750 mm
- Weight: 115kg (including trolley base and 2 vaporizers,
without cylinder)
- Operation Temperature: 10 ~ 40 °C
- Operation Humidity: ≤80% (non-condensing)
- Storage Temperature: -20 ~ 55 °C
- Storage Humidity: ≤93% (non-condensing)
Electrical Specifications
- Mains: 100 ~ 240 V AC, 50/60 Hz
- Battery: 24V DC, minimum 120 min
- Outlets: 4 on back, 1.5A individual
Pneumatic Specifications
- Gas Supply: Air, O2, N2O; 280 kPa ~ 600 kPa
- Flowmeters: O2 Range: 0~1 L/min; 1 ~ 10 L/min
N2O Range: 0~1 L/min; 1 ~ 10 L/min
Air Range: 0~1 L/min; 1 ~ 12 L/min
Auxiliary O2 Range: 0 ~ 15 L/min
- Gas System: Flowmeter backlight
Oxygen supply failure alarm
N2O cut-off system
O2 flush: 25 ~ 75 L/min
- ACGO: Optional auxiliary common gas outlet
- AGSS: Optional anesthetic gas scavenging system
Breathing System Specifications
- Oper ational Modes : Closed, Semi – closed, Semi – open
- CO2 Canis ter : 2 Loose fi l l ( 3 L) or 2 pr epacks ,
optional single canister (1.5 L)
- APL Range: Spontaneous br eathing (SP) – 70 cmH2O
- Mater ial : Autoclavable ( except O2 cel l and airway
pr es sur e gauge)
Vent ilat or Specif icat ions
- Driven Mode: Pneumatically driven and electronically
controlled
- Patient Types: Adult, Pediatric
- Ventilation Modes: IPPV, PCV, SIMV+PS, PS and Manual
- Setting Modes: Touch key & navigator wheel knob
- Tidal Volume: 20 ~ 1500 ml
- Ventilation Frequency: 4 ~ 100 bpm
- I:E Ratio: 4:1 ~ 1:8
- Pressure (inspired) Range: 5 ~ 70 cmH2O
- Pressure (support) Range: 3 ~ 50 cmH2O
- PEEP: Off, 3 ~ 30 cmH2O
- Tslope: 0 ~ 2 s
- Inspiratory Plateau: Off, 5% ~ 60% Ti
- Trigger Sensitivity: 1 ~ 15 L/min
- Compensation: Compliance and leakage compensation,
fresh gas compensation and altitude compensation
Ventilator Monitoring
- Display: 10.4” TFT color screen
- Pressure: Ppeak, Pplat, Pmean, PEEP
- Volumes: MV, Vt, Freq
- Gas: O2 Concentration, optional CO2, Agent and MAC
- Graph Display: P-t, F-t, P-V, F-V loops (can be saved),
optional CO2-t
- Alarm: High Airway Pressure/Low Airway Pressure
Continuous airway pressure
High Minute Volume/Low Minute Volume
High FiO2/Low FiO2
High Breath Rate
O2 Supply failure
Power failure
Apnea Alarm
Alarm Silence: 110 s
Vaporizer
- Supports two vaporizers
- Agent: Halothane, Enflurane, Isoflurane, Sevoflurane
- Installation Mode: Selectatec® with interlock,
optional standby vaporizer parking holder
- Filling Type: Pour Fill, Key Fill, Quik-Fil®
Call for order: 01401-241354